Scan your whole stack
Latest version: v1.103.0
The Cable Code was last scanned on 27 Nov 2026 at version 1.103.0. Risk score 0 of 100. No malicious behavior was detected.
| Version | Published | Status |
|---|---|---|
| 1.103.0 LATEST | 27 Nov 2026 | No rules fired |
| 1.101.0 | 13 Nov 2026 | No rules fired |
| 1.95.0 | 12 Nov 2026 | No rules fired |
| 1.83.0 | 10 Nov 2026 | Not shown |
| 1.77.0 | 10 Nov 2026 | Not shown |
Findings for v1.103.0. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.
The score describes 1.103.0; other versions have their own rules, not their own score.
What the probe observed on connect. Fields the probe did not learn are not shown — never guessed.
Find threats in your stack.
OX Radar can check high-priority threats, like critical package CVEs, against your context.
Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.
This server advertises the tools below. A tool list is an inventory of what the server can do — it is not a finding, and it is not part of the score.
Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. 5 free calls per caller per UTC day (with find_equivalents, overhead_conductor), then $0.10 USDC per call (x402).
Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its standard and source, diameter, weight, designation, current, voltage drop and short-circuit ratings, optional files (XML, DXF, SVG, CSV, GLB, STEP, PDF). Deterministic, no LLM; nominal values. Notes: thecablecode://guide/design_cable. 2 free designs per caller per UTC day, then $0.50 USDC per design (x402).
The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equivalent, close (the differences) or none (the reason). Deterministic, no LLM; never a statement of interchangeability. Notes: thecablecode://guide/find_equivalents. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).
A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code ("242-AL1/39-ST1A", EN 50182; "401-AL0/28-MEHST", FprEN 50540) or an EN 50182 Annex F table ("F.19"): stranding, areas, diameters, mass, strength and resistance as printed, with table and page. Deterministic, no LLM. Notes: thecablecode://guide/overhead_conductor. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).
Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a certificate or a type test. Notes: thecablecode://guide/check_cable. 2 free checks per caller per UTC day, then $0.50 USDC per check (x402).
Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and smallest thickness, screen, armour, diameters and standards, with page and row. An LLM (Claude) reads, deciding nothing; with standard set the rules check each row. Notes: thecablecode://guide/extract_datasheet. Price (USDC, x402): a paid call from the first document: $2.00 in USDC per document, no free allowance.
Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing sections, with pages. An LLM (Claude) copies values, deciding nothing. Waits up to about two minutes, then answers a poll link (GET /api/v1/tender/{job}); a PDF: POST /api/v1/tender. Notes: thecablecode://guide/read_tender. Always paid: $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages, USDC (x402).
Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender order (Markdown and text) and the required / offered schedule (CSV and JSON), REQUIRED filled with sources, OFFERED left for the bidder. Deterministic, no LLM; a draft to check. Notes: thecablecode://guide/write_specification. Always paid: $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30, USDC (x402).
What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, its designation, voltage, cores, section and metal; and spec_standards[], the families a spec may name in spec.standard. Takes only lang. Free, no LLM.
Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic K, DIN, Spanish, NEMA, Turkish, IS 10418 and makers' drums with sources, with barrel and load checks; reeling adds the NFPA 79 derating, lagging the handling block. Notes: thecablecode://guide/drum_fit. Free, outside the daily calls; deterministic, no LLM.
Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rule with its source and seen level, or null with the reason. Free, no LLM. Notes: thecablecode://guide/burial_depth.
The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenum ...), the rule lines with sources and seen levels; the US NEC Article 722 listing ladders. To read a printed class use decode_cable_code. Free, no LLM. Notes: thecablecode://guide/fire_class.
AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation constant in MΩ·km. Send awg or mm2, metal Cu (default) or Al. Free, no LLM. Notes: thecablecode://guide/awg_metric.
NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, against Table 1's fill limits, with the jam ratio; each area with its table. Free, no LLM. Notes: thecablecode://guide/conduit_fill.
Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the allowable values with sources. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/pull_cable.
NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/tray_fill.
How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. Choose the drum with drum_fit (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/drum_loading.
A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknown. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/cold_weather_check.
MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/mv_electrical.
Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/economic_size.
The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to record results in. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/commissioning_sheet.
End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kinds, outdoor creepage (IEC TS 60815-3), glands and cleats. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/cable_prep.
IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency ratings, banks, troughs, crossings. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/iec60287_rating.
Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/degassing_time.
An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a statement of interchangeability. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/equivalence_report.
The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).