Introducing The Sweep: OX’s New Live Security Research Series
Register Now
Breaking: The 2026 Vulnpocalypse Hits PHP: Four Critical RCEs, but How Dangerous Are They?
Read the Report
Are you exposed? Connect your apps in minutes.
Scan your apps free

The Cable Code

Latest version: v1.103.0

Overview

Last scanned
27 Nov 2026
Published
27 Nov 2026
MCP server Transport: Streamable HTTP Source: MCP Registry
13 Versions

Scan summary

The Cable Code was last scanned on 27 Nov 2026 at version 1.103.0. Risk score 0 of 100. No malicious behavior was detected.

  • Releases: 13 versions; the latest was published on 27 Nov 2026.
  • Findings: No rules fired in version 1.103.0.
  • MCP server: Runs over Streamable HTTP. It does not require authentication. It uses MCP protocol version 2025-06-18. Exposes 25 tools.

Versions

13 versions published
Versions and the rules that fired in each
VersionPublishedStatus
1.103.0 LATEST 27 Nov 2026 No rules fired
1.101.0 13 Nov 2026 No rules fired
1.95.0 12 Nov 2026 No rules fired
1.83.0 10 Nov 2026 Not shown
1.77.0 10 Nov 2026 Not shown

No rules fired in 1.103.0

Findings

Findings for v1.103.0. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.

The score describes 1.103.0; other versions have their own rules, not their own score.

Live check

What the probe observed on connect. Fields the probe did not learn are not shown — never guessed.

Reachable
YES
Transport
HTTP
Authentication
NONE — OPEN
MCP protocol
2025-06-18
Server
thecablecode 1.103.0
Tools advertised
25

OX Radar and Response Center

Find threats in your stack.

OX Radar can check high-priority threats, like critical package CVEs, against your context.

Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.

Capabilities

25 tools advertised

This server advertises the tools below. A tool list is an inventory of what the server can do — it is not a finding, and it is not part of the score.

decode_cable_code

Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. 5 free calls per caller per UTC day (with find_equivalents, overhead_conductor), then $0.10 USDC per call (x402).

Params code lang

design_cable

Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its standard and source, diameter, weight, designation, current, voltage drop and short-circuit ratings, optional files (XML, DXF, SVG, CSV, GLB, STEP, PDF). Deterministic, no LLM; nominal values. Notes: thecablecode://guide/design_cable. 2 free designs per caller per UTC day, then $0.50 USDC per design (x402).

Params sentence spec design lang formats installation fault_s load fault cpc nec test_variant

find_equivalents

The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equivalent, close (the differences) or none (the reason). Deterministic, no LLM; never a statement of interchangeability. Notes: thecablecode://guide/find_equivalents. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).

Params code design country standard lang

overhead_conductor

A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code ("242-AL1/39-ST1A", EN 50182; "401-AL0/28-MEHST", FprEN 50540) or an EN 50182 Annex F table ("F.19"): stranding, areas, diameters, mass, strength and resistance as printed, with table and page. Deterministic, no LLM. Notes: thecablecode://guide/overhead_conductor. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).

Params code table row core

check_cable

Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a certificate or a type test. Notes: thecablecode://guide/check_cable. 2 free checks per caller per UTC day, then $0.50 USDC per check (x402).

Params designation design construction standard

extract_datasheet

Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and smallest thickness, screen, armour, diameters and standards, with page and row. An LLM (Claude) reads, deciding nothing; with standard set the rules check each row. Notes: thecablecode://guide/extract_datasheet. Price (USDC, x402): a paid call from the first document: $2.00 in USDC per document, no free allowance.

Params url text hint standard

read_tender

Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing sections, with pages. An LLM (Claude) copies values, deciding nothing. Waits up to about two minutes, then answers a poll link (GET /api/v1/tender/{job}); a PDF: POST /api/v1/tender. Notes: thecablecode://guide/read_tender. Always paid: $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages, USDC (x402).

Params text hint lang

write_specification

Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender order (Markdown and text) and the required / offered schedule (CSV and JSON), REQUIRED filled with sources, OFFERED left for the bidder. Deterministic, no LLM; a draft to check. Notes: thecablecode://guide/write_specification. Always paid: $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30, USDC (x402).

Params sentence spec design installation fault_s drum cables requirements lang

design_presets

What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, its designation, voltage, cores, section and metal; and spec_standards[], the families a spec may name in spec.standard. Takes only lang. Free, no LLM.

Params lang

drum_fit

Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic K, DIN, Spanish, NEMA, Turkish, IS 10418 and makers' drums with sources, with barrel and load checks; reeling adds the NFPA 79 derating, lagging the handling block. Notes: thecablecode://guide/drum_fit. Free, outside the daily calls; deterministic, no LLM.

Params od length kg kind system max allowance freeboard D d W barrel_od free_height pool reeling layers lagging handling material lang

burial_depth

Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rule with its source and seen level, or null with the reason. Free, no LLM. Notes: thecablecode://guide/burial_depth.

Params country u place method

fire_class

The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenum ...), the rule lines with sources and seen levels; the US NEC Article 722 listing ladders. To read a printed class use decode_cable_code. Free, no LLM. Notes: thecablecode://guide/fire_class.

Params country place lang

awg_metric

AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation constant in MΩ·km. Send awg or mm2, metal Cu (default) or Al. Free, no LLM. Notes: thecablecode://guide/awg_metric.

Params awg mm2 metal k lang

conduit_fill

NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, against Table 1's fill limits, with the jam ratio; each area with its table. Free, no LLM. Notes: thecablecode://guide/conduit_fill.

Params raceway nipple cables

pull_cable

Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the allowable values with sources. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/pull_cable.

Params sentence spec design input full items lang pdf

tray_fill

NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/tray_fill.

Params input full items lang pdf

drum_loading

How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. Choose the drum with drum_fit (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/drum_loading.

Params input full items lang

cold_weather_check

A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknown. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/cold_weather_check.

Params sentence spec design input items lang

mv_electrical

MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/mv_electrical.

Params sentence spec design input items lang

economic_size

Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/economic_size.

Params sentence spec design input items lang

commissioning_sheet

The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to record results in. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/commissioning_sheet.

Params sentence spec design input items lang

cable_prep

End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kinds, outdoor creepage (IEC TS 60815-3), glands and cleats. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/cable_prep.

Params sentence spec design input full items lang pdf

iec60287_rating

IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency ratings, banks, troughs, crossings. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/iec60287_rating.

Params sentence spec design input items lang

degassing_time

Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/degassing_time.

Params sentence spec design input items lang

equivalence_report

An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a statement of interchangeability. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/equivalence_report.

Params sentence spec design input items lang

Where it’s listed

The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).

  • MCP Registry io.github.exquad/thecablecode

References

The publisher’s own links, as the registry reports them. These are not sources for the assessment on this page.

Powered by Read the latest findings

Scan your whole stack

Group 1261154050 1
Group 1261154050
 

From OX Research Newsroom

Plug and Pray: Your AI Agents Are Taking Orders From Strangers
Research

Plug and Pray: Your AI Agents Are Taking Orders From Strangers

Microsoft's Official agent framework Hijacked
AI & VibeSec

BREAKING: Hijacked Releases of Microsoft’s Official agent-framework Steals Azure and CI Credentials

Cry2Wolf: How to Tell a Real Bug from a Nothingburger
AI & VibeSec

Cry2Wolf: Not Every Branded Bug Deserves a Fire Drill

Frame 2085668439 (1)
Group 1261154229