Scan your whole stack
Are you using homebridge-lg-thinq-connect?
Find out what’s in your code.
Scan your apps free in minutes (opens in a new tab)Latest version: v3.1.0
homebridge-lg-thinq-connect was last scanned on 27 Nov 2026 at version 3.1.0. Risk score 0 of 100. No malicious behavior was detected.
| Version | Published | Status |
|---|---|---|
| 3.1.0 LATEST | 27 Nov 2026 | No rules fired |
| 3.0.0 | 27 Nov 2026 | Not shown |
| 2.0.3 | 27 Nov 2026 | Not shown |
| 2.0.2 | 27 Nov 2026 | Not shown |
| 2.0.2-beta.1 | 27 Nov 2026 | Not shown |
Findings for v3.1.0. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.
The score describes 3.1.0; other versions have their own rules, not their own score.
The publisher’s own README, as collected from the registry.
Shows LG ThinQ appliances in Apple Home through LG's official ThinQ Connect API. You sign in with a personal access token that LG issues, not your LG password, and the plugin uses LG's supported, documented API rather than the LG app's own sign-in.
Washers and dryers are supported: the time left, a notification when a cycle finishes or stops on an error, and sensors for automations. Air conditioners, dehumidifiers and range hoods are added too, checked against Home Assistant's data from real appliances. Other LG appliances (fridges, dishwashers, air purifiers, ovens and more) can be tried with the Experimental appliances setting; see Other appliances.
Each washer or dryer shows up as:
The log also notes LG's cycle count when it goes up, for machines that keep one, and when a Tub Clean starts it again. With debug logging on, it notes each dry's time and the usual one.
The names follow your machines' names in the ThinQ app, in title case ("Washer Finished", "Dryer Clean Lint Filter"). Renaming a tile in the Home app is kept. To shorten them all at once (say "Front Load Washer" to "Washer"), rename the machine in the ThinQ app: after the next Homebridge restart its tiles and sensors take the new name, except ones you renamed in the Home app. Entries under Options per appliance go by the ThinQ name, so update those too.
Tips for the Home app. You get one notification per finish. The Home app's notification names the room and the sensor, so keep the machine's name in each sensor's name (the default) if several appliances share a room. Sensors you only use for automations can be taken off the Home view (the sensor's settings, Include in Favorites off); the Remote Start sensor can be left out per appliance, and the phase, tub-clean, lint filter and vent check sensors are off unless you set them.
Machines with two drums (wash combos) show one set per drum. WashTower units, wash combos and other laundry models are experimental until someone with one confirms they work. The washer and dryer types are tested on an LG front-load washer (F3P2CYVAT) and dryer (RV13D4AMH).
With Allow starting and pausing on, tapping the machine's tile in the Home app pauses a running cycle, resumes a paused one, or starts a machine that's ready. LG only accepts this after Remote Start is turned on at the machine itself, a safety rule of LG's. Without it, the tap is refused, the tile goes back within a few seconds, and the log says why.
How Remote Start is turned on depends on the model; the manual says which button. On the tested machines: on the washer, hold Pre-wash for 3 seconds (after choosing the program); on the dryer, hold Energy Saver for 3 seconds, with the door closed. A Wi-Fi or remote symbol lights up, and the Remote Start sensor turns on. LG turns it off again after a while.
LG sometimes answers a start or pause with 2211 "Device Timeout" even though the machine did it. The plugin doesn't treat that as a failure: it logs it at info level and checks the machine, and the tile follows what the machine reports.
You can't pick the program, temperature or spin speed from the Home app: LG's API doesn't offer that. Choose those on the machine. A start from the Home app may run the machine's default program instead of the one on the dial: LG's API can only send "start". Seen on an LG washer (F3P2CYVAT): Speed Wash on the dial, started from the Home app, ran Normal; Home Assistant users report the same (Cotton on European models). When a washer's cycle time jumps right after a start like that, the log says so. Pausing and resuming aren't affected. So a remote start suits loads you'd run on the default program anyway; for anything else, start on the machine and use the Home app for pause, resume and the notifications.
npm install -g homebridge-lg-thinq-connect.Signed in to LG (US): found Front Load Washer, Dryer.
and then adds each appliance.What LG's error codes in the log mean:
| Code | Meaning | What to do |
|---|---|---|
| 1103, 1218, 1302 | The token isn't valid | Copy it again whole, or create a new one |
| 1303 | LG doesn't know this account | Create the token on the account the app uses |
| 1304 | New LG terms to accept | Open the ThinQ app and accept them |
| 1305, 1308 | The token lacks a permission | Create a new token with every permission ticked |
| 1306 | Too many requests | Nothing: the plugin slows down and retries |
| 1307, 1309 | Wrong country for this account | Set the country the account was created in |
| 1222 | The appliance isn't connected | Check it's on and on Wi-Fi in the ThinQ app |
| 2211 | LG didn't hear back from the appliance in time | Usually nothing: the command often worked anyway, and the tile follows the machine |
| 2301 | Remote control is off | Turn on Remote Start at the appliance |
| 2302, 2304 | Not possible right now (state, or switched off) | Try again when the appliance is ready |
The settings screen groups them the way they're saved in config.json (shown in brackets):
Find threats in your stack.
OX Radar can check high-priority threats, like critical package CVEs, against your context.
Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.
The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).
The publisher’s own links, as the registry reports them. These are not sources for the assessment on this page.