Introducing The Sweep: OX’s New Live Security Research Series
Register Now
Breaking: The 2026 Vulnpocalypse Hits PHP: Four Critical RCEs, but How Dangerous Are They?
Read the Report
Are you exposed? Connect your apps in minutes.
Scan your apps free

modbus-event-connect

Latest version: v0.11.2

Overview

Last scanned
27 Nov 2026
Published
27 Nov 2026
PyPI package Publisher: HairingX
0 Stars
2 Forks
15 Versions
2.4K Downloads
Python Repo language

Scan summary

modbus-event-connect was last scanned on 27 Nov 2026 at version 0.11.2. Risk score 0 of 100. No malicious behavior was detected.

  • Releases: 15 versions; the latest 3 were published within 3 days (25–27 Nov 2026).
  • Findings: No rules fired in version 0.11.2.
  • Downloads: 2,378 downloads.

Versions

15 versions published
Versions and the rules that fired in each
VersionPublishedStatus
0.11.2 LATEST 27 Nov 2026 No rules fired
0.11.1 26 Nov 2026 No rules fired
0.11.0 25 Nov 2026 No rules fired
0.10.1 20 Nov 2026 Not shown
0.10.0 19 Nov 2026 Not shown

No rules fired in 0.11.2

Findings

Findings for v0.11.2. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.

The score describes 0.11.2; other versions have their own rules, not their own score.

README

The publisher’s own README, as collected from the registry.

Modbus Event Connect

Read and write devices over Modbus and micro_nabto in Python, and be told when a value changes.

A device is described once, as a model. The library then takes care of the rest:

  • reading only what is needed, as often as it is needed, in as few requests as possible
  • telling you when a value changes
  • checking a value before it is written
  • retrying and recovering when the device is busy or goes away
  • saying how trustworthy every value is, so "offline", "no reading" and a real value never look alike

Which part is for you

You are... Read
Building an application for a device that already has a model Part 1: Using a device
Describing a new device: its registers, units and settings Part 2: Describing a device
Working on the library itself docs/design.md
pip install modbus-event-connect

How the pieces fit

Model    what the device is and how it is talked to: ModbusModel or        (Part 2)
         MicroNabtoModel - its points, how to decode them, its timing
Device   where it is: ModbusDevice or MicroNabtoDevice, given the models      (Part 1)
Client   joins them: connect, subscribe, run, write                           (Part 1)

A model is locked to one protocol and says everything about how its unit behaves on it, read top to bottom in one file. A device library keeps each model in a file of its own and lists the models once; its create_client writes out what is needed before the model is known. An application only says where the device is.

A point is one value the device has, such as a temperature or a setting. Its key, Key("temperature", float), names it everywhere and says what its value is. A key is its text wherever it is stored, and a type checker knows from it what reading the point gives and what writing it takes.

Keys, values, points by their behaviour, the scheduling of reads and what a write or a change sets off are those of event_connect, the protocol-free core this library is built on; they are imported from here under the same names.

Everything is imported from four places. The modules inside them are internal, and may change in any release.

Import from For
modbus_event_connect the client, values, errors, and what a model is made of
modbus_event_connect.modbus Modbus: the connection, the device, register kinds and numbering
modbus_event_connect.micro_nabto micro_nabto: discovery, the session, the device, register kinds
modbus_event_connect.testing testing a model: simulated devices, a fake clock, the model walker

Part 1: Using a device

A complete program

import asyncio
from my_devices import TARGET, TEMPERATURE, create_client   # see Part 2

def on_change(key, old, new):
    print(f"{key}: {new.value} ({new.quality.name})")

async def main():
    client = create_client(host="<device-ip>", unit_id=1)
    await client.connect()                  # reads every point once
    client.subscribe(TEMPERATURE, on_change)
    await client.write(TARGET, 21.5)
    polling = asyncio.create_task(client.run())   # reads whatever is due, until cancelled
    try:
        await asyncio.sleep(3600)
    finally:
        polling.cancel()
        await client.disconnect()

asyncio.run(main())

run() reads whatever is due, whenever it is due, until it is cancelled - it never ends by itself - and is woken when a subscription, a refresh or a write makes something due sooner. While the client is not connected - before connect(), or after disconnect() - it waits until it is. A poll that raises is logged, the first of a run of failures as an error with its traceback, and polling goes on after a pause. It waits on the client's clock, as every pause the client makes does: a test that gives the client a FakeClock moves it on with clock.advance().

A program with its own loop calls poll() instead, which reads the points that are due. A call when nothing is due returns at once without contacting the device; seconds_until_next_poll() says how long until something is.

Connecting

A device library's create_client does this for you. Building one by hand, every value is written out; none has a default but a protocol's own facts, such as its port:

from modbus_event_connect import CircuitBreaker, Exponential, Fixed, Retry
from modbus_event_connect.modbus import ModbusDevice, ModbusTcpConnection
from modbus_event_connect.micro_nabto import MicroNabtoDevice
import my_blinds, my_heating, my_devices, my_ventilation   # each lists its models

# Modbus TCP, one device; once 3 requests in a row went unanswered, asked again 2, 4 and 8 s
# later, then every 10 s. A request waits as long as the model says its unit answers within,
# and timeout_margin more, for the network.
device = ModbusDevice.tcp("<device-ip>", unit_id=1, models=my_devices.MODELS, timeout_margin=2.5,
                          connect_timeout=3.0, frame_gap=0.0,
                          reconnect=CircuitBreaker(after=3, retry=Retry(Exponential(2.0, factor=2.0, max=10.0), None)))

# Several Modbus devices behind one gateway, sharing its connection, each with its own breaker
gateway = ModbusTcpConnection("<gateway-ip>", connect_timeout=3.0, frame_gap=0.0)
slowly = CircuitBreaker(after=3, retry=Retry(Exponential(10.0, factor=2.0, max=120.0), None))
heating = ModbusDevice(gateway, 1, reconnect=slowly, models=my_heating.MODELS, timeout_margin=2.5)
blinds = ModbusDevice(gateway, 3, reconnect=slowly, models=my_blinds.MODELS, timeout_margin=2.5)

# micro_nabto; with device_id, the device is found again if its address changes
ventilation = MicroNabtoDevice.udp("<email-paired-with-the-device>", host="<device-ip>",
                                   device_id="<device-id>", models=my_ventilation.MODELS,
                                   timeout=1.0, retries=2, session_idle=12.0, rediscovery_timeout=3.0,
                                   rediscovery_resend=0.5, answer_wait=5.0,
                                   reconnect=CircuitBreaker(after=1, retry=Retry(Fixed(5.0), None)))

Behind a gateway, a device that stops answering does not slow down the others, and each request waits as long as its own unit needs.

A device is given every model it may turn out to be, of its own protocol only: a type checker refuses a MicroNabtoModel given to a ModbusDevice. Once the client has chosen the model, it tells the device with use(model), and the device talks to it as that model says. Until then it asks as cautiously as any of its models needs: the fewest registers in one read, the longest wait for an answer. A model the device was not given raises ModelError, and so does one given twice.

A micro_nabto device says what it is when you connect. Give the client a function instead of a model, and it picks one of the device's models from that:

def pick_model(identity):
    return VENTILATION if identity["device_model"] == 1140 else None

client = Client(ventilation, pick_model, offline_after_intervals=1, level=Level.DOCUMENTED)

offline_after_intervals is how many reads of the chosen model's fastest poll rate the device may leave unanswered before it counts as not answering; see Connection state. level is which of the model's points the client uses; see Levels and candidates.

micro_nabto devices on the local network are found with discover, which writes out how long it searches and how often it asks again: await discover(timeout=2.0, resend=0.5, target=BROADCAST). Each answer is a DiscoveredDevice with its device_id, host and port.

Once connected, client.model is the model chosen and client.identity what the device reported about itself, with what the model's identity points read.

connect() raises when it cannot finish:

Error Meaning
CannotConnectError The device could not be reached, or did not answer every read. Try again later.
AuthenticationError A micro_nabto device refused the email. Ask the user to check it.
UnsupportedDeviceError The device answered, but no model matches it. Its identity is what the device reported.

Reading values

client.subscribe(key, callback) calls callback(key, old, new) at once with the current value, then on every change. old is None the first time. It returns a function that unsubscribes.

client.value(key) gives the current value at any time, or None while the unit has none. Its type follows the key: client.value(TEMPERATURE) is a DataValue[float], and a key of another type than the model gives the point raises TypeError.

Every value is a DataValue with .value, .quality, .timestamp, and .raw: what the device answered, before it was decoded.

Quality Meaning Show it as
GOOD A real value. the value
NO_DATA The device says it has no reading, such as a sensor not fitted, or sent a number no state names. unknown
STALE The last read failed. .value and .timestamp are the last good read's. the value, or unavailable
OFFLINE Something behind the device is not answering. It will come back. unavailable
MISSING This device does not have the value. leave it out

How often values are read

Every point is read once when connecting. After that, a point is read on its poll rate - FAST, MEDIUM, SLOW, RARE, or STATIC, once when connecting - while someone subscribes to it. How many seconds each rate is, the model says, for its own unit; nothing outside the model changes it.

To read now, call await client.refresh([TEMPERATURE]). refresh(PollRate.SLOW) reads a whole poll rate, and refresh() reads everything. subscribe(key, callback, poll=False) is told about changes without asking for the point to be read on a timer. A key no model of the client has raises KeyError, before connect() too.

client.set_scheduled_polling(False) stops reading on the schedule - every poll rate, and the checks for whether the unit has changed. poll() then reads only what refresh() and writes ask for, and a read that finds a point gone still has its part of the unit checked. set_scheduled_polling(True) reads at once what has become due meanwhile.

Riding out failures

How a device is asked again is assembled from standard parts that every protocol shares: waits (Fixed, Exponential, Steps, Jitter), stops (Attempts, Within, combined with |), Retry, which puts a wait and a stop together, and CircuitBreaker, which stops asking a device that has left requests unanswered.

Reconnecting is stated by whoever creates the device, as reconnect, a CircuitBreaker, and nowhere else: how soon a silent device should be asked again depends on how it is reached, not on what it is. It has no default. The breaker opens once after requests in a row went unanswered - for micro_nabto, handshakes - and the device is not asked until its retry lets a probe through; asking again reopens a closed link, and an answer closes the breaker. connect() closes it too. Before each probe, await retry.ready() is asked: a subclass of Retry can check something first, and a probe it refuses keeps the breaker open as long again.

reconnect=CircuitBreaker(after=3, retry=...) Once 3 requests in a row went unanswered, asks again
Retry(Exponential(2.0, factor=2.0, max=10.0), None) after 2, 4 and 8 s, then every 10 s
Retry(Fixed(60.0), None) every minute
Retry(Exponential(2.0, factor=2.0, max=10.0), Attempts(8)) as the first, and gives up at the eighth opening
Retry(Steps(2.0, 5.0, then=Fixed(60.0)), Within(3600.0)) after 2 and 5 s, then every minute, for an hour
NO_RETRY only on connect()

What the model states is about its unit itself, and has no default either:

OX Radar and Response Center

Find threats in your stack.

OX Radar can check high-priority threats, like critical package CVEs, against your context.

Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.

Where it’s listed

The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).

  • pypi-releases modbus-event-connect

References

The publisher’s own links, as the registry reports them. These are not sources for the assessment on this page.

Powered by Read the latest findings

Scan your whole stack

Group 1261154050 1
Group 1261154050
 

From OX Research Newsroom

Vulnerability Insights

OpenSSH Password Authentication Bypass on Alpine Linux (*sshole) – CVE-2026-123158

Copy of Template Design OX Blog (2)
Research

NGINX2Root: Five Critical NGINX Flaws Expose Web Servers to Remote Code Execution

Microsoft's Official agent framework Hijacked
AI & VibeSec

BREAKING: Hijacked Releases of Microsoft’s Official agent-framework Steals Azure and CI Credentials

Frame 2085668439 (1)
Group 1261154229