stl2bem

Computes the sound pressure on and around a rigid object from a closed STL mesh, with the boundary element method.
It runs on a CPU or an NVIDIA GPU and writes tables over directions and frequencies, for example the response of
every microphone on a device, as HDF5 or SOFA files.

Plane waves passing six objects modeled in Fusion (3,800 to 12,000 triangles each): real part of the total
pressure on a slice through each object, over one period. Surface pressure and cavity resonances of the same
objects are in docs/validation.md.
Install
pip install stl2bem # NumPy, SciPy, h5py (CPU)
pip install "stl2bem[prep,sofa]" # optional: merging CAD parts, SOFA export
pip install cupy-cuda12x # optional GPU backend; pick the CuPy package of your CUDA version
The examples and figures need the repository: git clone https://github.com/Kwon-Junhyeong/stl2bem.
Quick start
stl2bem --stl device.stl --units mm --mics mics.csv --out out/ --dry_run # check mesh, microphones, resources
stl2bem --stl device.stl --units mm --mics mics.csv --out out/ # 0-8 kHz, 1-degree direction grid
stl2bem --stl device.stl --units mm --mics mics.csv --out out/ --source_distance 0.5 # sources 0.5 m away
mics.csv has one x, y, z row per microphone, in the STL units; each microphone is moved to the closest point of
the surface. Without --source_distance the sources are plane waves (far field). The dry run prints the distance
2D²/λ beyond which that holds for your body; closer sources need --source_distance. It also estimates the
run time: the default grid of 65,160 directions takes minutes on a GPU but hours on a CPU, and --n_el 19
(10 degrees in elevation) makes a CPU run about eight times faster. stl2bem --help lists all options.
From Python:
import numpy as np
from stl2bem import build_mesh, surface_receivers, solve_table, spherical_doa_grid
mesh = build_mesh("device.stl", units="mm", recenter="none")
mics, weights, _ = surface_receivers(np.loadtxt("mics.csv", delimiter=",") / 1000, mesh)
doa, az, el = spherical_doa_grid(360, 19) # 1 deg azimuth, 10 deg elevation
freqs = np.linspace(0, 4000, 129)
solve_table(mesh.verts, mesh.tris, mesh.centroids, mesh.normals, mesh.areas, freqs, doa, "table.h5",
receivers=mics, receiver_elements=weights)
The pressure on a plane through the body, as in the gallery:
from stl2bem.viz import plane_grid, field_on_points
pts, shape = plane_grid(center=(0, 0, 0), u=(1, 0, 0), v=(0, 0, 1), half=(0.2, 0.2), n=(241, 241))
field = field_on_points(mesh, 2000.0, doa=(1, 0, 0), points=pts).reshape(shape) # NaN inside the body
The localization error that the body causes for a free-field SRP-PHAT:
from stl2bem.analysis import load_table, free_field, doa_error, summarize
body = load_table("table.h5", elevations=[0])
print(summarize(doa_error(body, free_field(body), band=(300, 3000), method="srp-phat", search="azimuth")))
Output
One HDF5 file per body:
| dataset |
shape |
meaning |
p |
(R, D, F) complex64 |
total pressure at receiver r for source d at frequency f, relative to the incident pressure at the origin |
doa_grid |
(D, 3) |
unit vectors towards the sources; az x el grids are stored az-major (i_az * n_el + i_el) |
source_positions |
(D, 3) |
point sources only: their positions (m) |
freqs |
(F,) |
Hz |
positions |
(R, 3) |
where p is evaluated (m, mesh frame); centroids is an older name for the same array |
chief_points |
(N_c, 3) |
only when CHIEF is used: the interior points |
Attributes hold the mesh report, the solver options and the convention. --sofa (or
python -m stl2bem.sofa table.h5) also writes the table as a SOFA file (AES69, GeneralTF).
Convention. e^{+jωt}, incident wave exp(+jk d·r). For a source signal s(t) from direction d, the FFT/STFT bin
(usual e^{-jωt} kernel) at microphone m is S(ω)·p[m, d, ω], so tables and FFT-domain signals combine directly
without conjugation. The phase reference is the center of the bounding box (--recenter bbox); --recenter none
keeps the CAD origin.
Accuracy

Rigid sphere with 5,120 elements at ka = 3.7 against the exact solution: the median difference is 8.6 × 10⁻⁴ of
the incident amplitude. The singular part of the integrals is evaluated exactly, and microphones on the surface are
second-order accurate, also on edges and vertices.

The six gallery meshes solved again with bempp-cl, which uses a different
formulation (Burton-Miller, linear elements): the fields differ by 0.01-0.4 % (median) and the resonance
frequencies by at most 0.5 %. One frequency with 6,840 directions takes 1 s for 4,800 elements and 11 s for
14,700 on an RTX 4060 Ti (8 GB).
Convergence, the comparison with the original code, resonances and timings: docs/validation.md.
Equations and implementation: docs/method.md.
Preparing CAD
The solver needs one closed, consistently oriented surface. A single solid exported from CAD usually is one (all
gallery models are); an assembly usually is not, because its parts overlap. stl2bem-prep merges the parts:
stl2bem-prep chassis.stl board.stl battery.stl --pitch 8 --units mm --out body.stl
It voxelizes the parts (pitch = element size), fills enclosed cavities and extracts a closed surface. Features
smaller than the pitch disappear and thin plates become one pitch thick; --align_z keeps a flat microphone board
flat. In Fusion, set the maximum edge length of the STL export to about λ/6 at the highest frequency; the mesh
report prints the frequency limit from the longest element edge and warns when some elements are larger than λ/6
at the highest frequency (CAD exports are often non-uniform).
Limits
- Rigid bodies in free space: no absorption, no vibrating surfaces, no floor or walls.
- Dense matrices: for N elements the GPU needs about 2.5 GB + 20 bytes × N² (an 8 GB GPU handles about 15,000
elements) and the CPU about 1.5 GB + 55 bytes × N² of RAM; time grows with N³. The dry run prints both.
- CHIEF points need room inside the body. Thin-walled objects (in the gallery, the bottle and the pipe) are solved
with the CBIE alone, which is safe there: their irregular frequencies start near c / 2t for wall thickness t,
far above the band the mesh resolves.
--formulation burton-miller is experimental: as accurate as the default away from resonances, but it damps
sharp cavity resonances. See docs/method.md.
Used in
An earlier version of this solver computed the microphone responses of a robot body in:
License