Scan your whole stack
From OX Research Newsroom
Latest version: v1.2.0
Spark Pack was last scanned on 27 Nov 2026 at version 1.2.0. Risk score 0 of 100. No malicious behavior was detected.
| Version | Published | Status |
|---|---|---|
| 1.2.0 LATEST | 27 Nov 2026 | No rules fired |
| 1.1.0 | 13 Nov 2026 | No rules fired |
Findings for v1.2.0. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.
The score describes 1.2.0; other versions have their own rules, not their own score.
What the probe observed on connect. Fields the probe did not learn are not shown — never guessed.
Find threats in your stack.
OX Radar can check high-priority threats, like critical package CVEs, against your context.
Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.
This server advertises the tools below. A tool list is an inventory of what the server can do — it is not a finding, and it is not part of the score.
Lists Spark Pack's tools, the regulations edition it targets, what it covers (nations, circuit types, cable types, installation methods) and what it deliberately does not do. Free, needs no input.
Sizes a UK final circuit or sub-main and shows the working: design current (with cooker diversity), protective device rating, the smallest cable size that passes current-carrying capacity, voltage drop (3% lighting, 5% other) and earth fault loop impedance (Zs against the maximum for B, C or D breakers), plus a cpc adiabatic check. Returns `recommended` (size and every check with status pass, fail, indicative_pass, needs_input), `sizes_considered` (one line per size), `must_check_against_regs` (
Answers whether domestic electrical work in England or Wales must be notified to building control under Part P of the Building Regulations, with the reason and what to do next (self-certify through a competent person scheme within 30 days, or tell building control before starting). England and Wales differ: in Wales kitchens and outdoor areas are still special locations. Returns `notifiable` (true or false), `answer`, `reason`, `what_to_do`, `must_check` and sources. Scotland and Northern Irelan
Returns the fields an Electrical Installation Certificate (eic), Minor Electrical Installation Works Certificate (minor_works) or Electrical Installation Condition Report (eicr) needs, as a JSON Schema the assistant fills from the job notes and test readings (spark-pack-certs-1.0 (for BS 7671:2018+A4:2026 certificates)). Includes which certificate to use when, and the contractor block prefilled from `trade` if given. check_certificate checks the filled object. Field names are Spark Pack's own; t
Checks a filled EIC, Minor Works certificate or EICR (shape from get_certificate_schema) and returns `ready_to_transfer`, every missing required field by path, errors (readings that fail: insulation resistance under 1 megohm at 500 V, measured Zs above the maximum for the breaker, RCD trip times too slow, wrong polarity, an EICR marked satisfactory with a C1 or C2) and warnings (Zs above 80% of maximum, mismatched ring readings, low insulation resistance). Contractor fields left blank are filled
For solar PV, batteries, V2G chargers, EV chargers and heat pumps in Great Britain: says which network operator process applies and when. Generation: G98 (fully type tested, 16 A / 3.68 kW per phase or less: install, then notify within 28 days) or G99 (apply and wait for acceptance before installing), counting existing generation and battery inverters. Demand: the ENA EV charge point and heat pump form (connect and notify within 28 days if every criterion is met, otherwise apply first), with eac
Looks up, live from official open data, what applies at the customer's postcode before solar PV, battery, EV charger, external cabling, rewire or consumer unit work: listed buildings, conservation areas, Article 4 directions, World Heritage Sites, National Landscapes, scheduled monuments and flood risk zones (planning.data.gov.uk, England, councils that publish). Returns each constraint found with its source link, what it means for the electrical work (listed building consent, solar on a wall fa
Checks the electrician's own business details (Nero Trade Profile v1: trading name, Companies House number, competent person scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration or company number. The same object, given as `trade` to the other tools, prefills certificates and grid forms. Spark Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exch
The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).
The publisher’s own links, as the registry reports them. These are not sources for the assessment on this page.