Introducing The Sweep: OX’s New Live Security Research Series
Register Now
Breaking: The 2026 Vulnpocalypse Hits PHP: Four Critical RCEs, but How Dangerous Are They?
Read the Report
Are you exposed? Connect your apps in minutes.
Scan your apps free

iobroker.faikout

Latest version: v1.2.2

Overview

Last scanned
23 Nov 2026
Published
23 Nov 2026
npm package Publisher: bluefox, smarthomeelektroniker
0 Stars
2 Forks
20 Versions
1.7K Downloads
JavaScript Repo language

Scan summary

iobroker.faikout was last scanned on 23 Nov 2026 at version 1.2.2. Risk score 0 of 100. No malicious behavior was detected.

  • Releases: 20 versions; the latest 5 were published within 5 days (19–23 Nov 2026).
  • Findings: No rules fired in version 1.2.2.
  • Downloads: 1,669 downloads.

Versions

20 versions published
Versions and the rules that fired in each
VersionPublishedStatus
1.2.2 LATEST 23 Nov 2026 No rules fired
1.2.1 23 Nov 2026 No rules fired
1.2.0 22 Nov 2026 No rules fired
1.1.0 22 Nov 2026 Not shown
0.2.1 19 Nov 2026 Not shown

No rules fired in 1.2.2

Findings

Findings for v1.2.2. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.

The score describes 1.2.2; other versions have their own rules, not their own score.

README

The publisher’s own README, as collected from the registry.

ioBroker.faikout

Connect Daikin air conditioners equipped with a faikout module to ioBroker — purely over MQTT, entirely local, no cloud and no vendor API.

The adapter brings its own MQTT broker. You point the faikout modules at it and that is all; no separate broker, no mqtt adapter instance, and no interference with any MQTT setup you already run.

Why a dedicated adapter

A faikout module also emulates the old local Daikin HTTP API, so it can be used with the daikin adapter. Over MQTT, however, it exposes considerably more — in particular values the HTTP API does not provide at all:

Value HTTP (daikin adapter) MQTT (this adapter)
Indoor humidity not reported yes
Energy counters (total / heating / cooling) not reported yes
Current power draw not reported yes
Compressor speed reported as 0 yes
Fan speed not reported yes
Refrigerant temperature not reported yes
Demand limit, louvre angle, presets not reported yes
WiFi and device diagnostics version only yes

Data points are created dynamically

A faikout module only publishes a field when the attached air conditioner actually supports it, and its own settings can hide further ones. There is therefore no fixed list of fields: the adapter creates exactly the data points it receives and silently omits the rest. Two units of different models will legitimately end up with different object trees.

Fields the adapter does not know yet are still created, with a type derived from the value, and noted in the log.

Objects are grouped per device:

  • <device>.control.* — writable: power, mode, target temperature, fan, swing, preset, demand, econo, powerful, comfort, streamer, sensor, LED, quiet, humidify. selectedMode is the operating mode without "off": while the unit runs it equals mode, while it is off it keeps the mode set last (taken from the module's native status). Writing it sends the mode and switches the unit on.
  • mode, fan, swing and preset are text, as the module speaks them. Each has a numeric twin (modeNum, fanNum, swingNum, presetNum) with common.states such as {0: "off", 1: "heat_cool", 2: "cool", 3: "heat", 4: "dry", 5: "fan_only"} for Lovelace and other tools that expect numbers. Both are writable and mean the same: a command on either sends exactly one command to the module (as text); both are set with ack=true when the module confirms. The numbers are fixed; new values of a future firmware are appended.
  • <device>.status.* — readings: temperatures, humidity, energy, power, compressor and fan speed
  • <device>.info.* — device diagnostics: IP, WiFi signal, uptime, firmware

Setup

  1. Install the adapter and open the instance configuration.
  2. Choose the broker port (default 1888). It must not collide with another MQTT broker. Optionally set a user name and password; leaving the user name empty accepts unauthenticated connections, which is the usual case inside a home network.
  3. Open the web interface of each faikout module, go to Settings → Basic and set MQTT host to <ioBroker IP>:<port>. The module reconnects on its own. The tab Find modules shows the exact value to copy (see below).
Internal or external broker

By default the adapter runs its own MQTT broker – nothing else has to be installed, the modules only point to it. In the tab MQTT broker you can choose an external broker instead (for example Mosquitto or the ioBroker MQTT adapter): the adapter then connects as a client with address, port, optional TLS, user name, password, client ID and an optional topic prefix. "Test connection" checks the values of the form before saving and says whether the broker is reachable, rejects the sign-in or does not answer.

With an external broker the adapter's own broker does not run and its port becomes free. The modules must point to the external broker themselves (module setting mqtthost); the adapter does not change that automatically – the tab "Find modules" shows which modules still point elsewhere and can switch one over. Switching between the two modes loses no data; the adapter restarts after saving.

Find modules

The tab Find modules in the instance settings helps with step 3:

  • Address for modules is the address under which the modules reach this ioBroker. It is pre-filled from the network interfaces of the host. If only Docker addresses (172.16.0.0/12) are found, enter the address of the Docker host yourself. Below it the ready-to-copy value for MQTT host (address:port) is shown.

  • Search asks once via mDNS for _http._tcp (every faikout module announces its web interface there) and reads the settings page /revk-settings of every candidate - read only, with a 2 s timeout and at most 4 requests at a time. Nothing is changed on the modules, and there is no background or scheduled search. Answers repeated by an mDNS reflector (e.g. a UniFi gateway) are attributed to the address in the A record, not to the reflector.

  • Check address reads the settings page of one IP address or host name - useful in Docker (bridge network), where mDNS does not reach the modules. There is no range scan.

  • The result lists name / host name, IP, firmware / hardware and the status: connected to this adapter, set to this adapter but not connected, no MQTT broker set, other MQTT broker, settings protected by password, or web login required.

  • Connect a module sets the MQTT host of ONE module to this adapter: choose the module from the search, click Check (fresh read of the module, preview of host name, IP, firmware and MQTT host old → new), then Connect and confirm. If the module currently uses another MQTT broker, "Replace other broker" has to be ticked as well. Right before saving the module is read again; if anything changed since the check, nothing is saved. The module gets one POST with mqtthost=<address>:<port> (plus MQTT user/password if this adapter has a user) and restarts; it has to report to this adapter within 90 s. Restore writes the MQTT host read before back (an old MQTT password cannot be read back - you get a warning if it was changed). A settings password of the module is used for that one action only and never saved. Nothing else is changed: no second broker, no firmware update, no OTA settings, and never several modules at once.

Values from the modules' settings forms (broker, user, passwords) are neither logged nor saved.

Running ioBroker in Docker

The broker port has to be published by the container, otherwise the modules cannot reach it. Add a port mapping for the configured port.

Module settings for the complete set of data points

What the adapter can show depends on the settings in the faikout module (web interface, Settings; most of them sit under the Advanced settings; older firmware spells them without the dot, e.g. haenable, nohumidity). These are the relevant ones:

Setting Required value Effect
MQTT host (Basic) <ioBroker IP>:<port> Connects the module to the adapter's broker.
ha.enable ("Home Assistant") on (default) The module publishes its readings (state/<name>) only while this is on. Off means: diagnostics only, no temperatures, energy, mode etc. — the adapter then logs a warning.
ha.fanrpm on (recommended) Fan speed status.fanfreq in rpm instead of Hz (default: Hz, one decimal). The adapter detects the unit itself (from the module's Home Assistant discovery) and sets it on the state; rpm is just more precise.
ha.comprpm on (recommended) Compressor speed status.comp in rpm instead of Hz (default: Hz). Detected automatically as well.
ha.switches on Adds autoe (main switch of the module's own automation) to the readings.
no.hvacaction off (default is on) Adds action — what the unit is actually doing (heating, cooling, idle …).
no.humidity off (default) Humidity hum. Only switch it on if the unit has no humidity sensor.
no.demand off (default) Demand limit demand.
no.led off (default is on) LED control — only if the unit's display LED can be switched.
no.humidify off (default is on) Humidifier control — only for units with a humidifier.
other no.* (econo, powerful, comfort, streamer, quiet, sensor, swingv, swingh, flap, antifreeze) off (default) Each one hides the matching function. Switch on only for functions your unit really lacks.
livestatus on (recommended) Reports immediately instead of every reporting seconds, see below.
reporting 60 (default) Interval of the periodic report in seconds.

No setting is needed for energy counters, power draw, compressor and fan speed, refrigerant and outside temperature: the module reads them from the unit on its own. Whether they appear depends only on the model — a unit that does not report a value simply has no data point for it.

Faster feedback

Out of the box a module reports its state every 60 seconds (reporting setting), so a command is only confirmed with the next report — expect up to a minute. Enabling livestatus in the module's Extra settings makes it report immediately.

Settings the air conditioner does not accept

A module sends a setting to the air conditioner and reads it back. If the unit still reports its old value after several rounds (s21.tries, 10 by default), the module drops the change, shows the value of the unit again and publishes the rejected fields on error/<name>/failed-set. Until then the module already shows the requested value, so it looks as if something had reset it.

The adapter logs this as a warning (… the air conditioner did not accept demand=90 …) and stores the last rejection in <device>.info.failedSet as JSON with the requested values and the time: {"time":"2026-11-05T14:40:51.085Z","settings":{"demand":90}}. The adapter itself does not send anything in this situation.

Known case: demand control (control.demand). Some units acknowledge the command but keep reporting 100 % — seen on units that still have Daikin's own WiFi adapter fitted. The module can only pass on the percentage; the modes of Daikin's app (off / automatic / fixed) are not part of what is known about the S21 interface. Econo is only taken over while the unit is running.

Lovelace, type detector and other tools that expect numbers

The module speaks text (mode = "cool"), and the text states stay the main form for scripts, vis and the device cards. Lovelace, however, converts the keys of common.states to numbers when it writes a climate entity; with text keys this gives NaN and the command is lost. Use the numeric twins in <device>.control.* for such tools:

State Role Values
modeNum level.mode.airconditioner 0 off, 1 heat_cool, 2 cool, 3 heat, 4 dry, 5 fan_only
fanNum level.mode.fan 0 auto, 1 night, 2 low, 3 lowMedium, 4 medium, 5 mediumHigh, 6 high
swingNum level.mode.swing 0 off, 1 on, 2 vertical, 3 horizontal, 4 both, 5 comfort, 6 horizontalComfort
presetNum level.mode 0 home, 1 eco, 2 boost

The roles let the type detector find them as part of an air conditioner. Writing 2, "2" or the label "cool" to modeNum sends one command cool to the module; modeNum and mode are both set with ack=true when the module confirms. A value outside the list is discarded with a warning in the log. The twins are created with the first report of a module after the update.

Climate control

OX Radar and Response Center

Find threats in your stack.

OX Radar can check high-priority threats, like critical package CVEs, against your context.

Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.

Where it’s listed

The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).

  • npm iobroker.faikout

References

The publisher’s own links, as the registry reports them. These are not sources for the assessment on this page.

Scan your whole stack

Group 1261154050 1
Group 1261154050
 

From OX Research Newsroom

CVE

Java4Shell (CVE-2026-114938): Easy to Crash, Hard to Exploit — Less Than 0.12% of JVMs Estimated at Risk of RCE

Copy of Template Design OX Blog (1)
Research

Thousands Of GitHub Accounts Hijacked With wfx-loot CI Secret Stealing Malware Via GitHub Actions & npm

Copy of Template Design OX Blog (2)
Research

NGINX2Root: Five Critical NGINX Flaws Expose Web Servers to Remote Code Execution

Frame 2085668439 (1)
Group 1261154229