Introducing The Sweep: OX’s New Live Security Research Series
Register Now
Breaking: The 2026 Vulnpocalypse Hits PHP: Four Critical RCEs, but How Dangerous Are They?
Read the Report
Are you exposed? Connect your apps in minutes.
Scan your apps free

fast-hrv

Latest version: v0.10.0

Overview

Last scanned
29 Nov 2026
Published
29 Nov 2026
PyPI package Publisher: omrylcn
4 Stars
0 Forks
1 Versions
Rust Repo language

Scan summary

fast-hrv was last scanned on 29 Nov 2026 at version 0.10.0. Risk score 0 of 100. No malicious behavior was detected.

  • Releases: First and only release on 29 Nov 2026.
  • Findings: No rules fired in version 0.10.0.

Versions

1 version published
Versions and the rules that fired in each
VersionPublishedStatus
0.10.0 LATEST 29 Nov 2026 No rules fired

No rules fired in 0.10.0

Findings

Findings for v0.10.0. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.

The score describes 0.10.0; other versions have their own rules, not their own score.

README

The publisher’s own README, as collected from the registry.

fast-hrv

Heart rate variability (HRV) from ECG, in Rust: from the raw signal to R peaks, artifact handling and 54 HRV metrics, offline or packet by packet, with results that match NeuroKit2 where the methods are the same.

Cleaning, R peaks, Kubios correction and all HRV metrics on a 512 Hz synthetic ECG, one thread, NeuroKit2 0.3.0 vs fast-hrv 0.10.0, Intel i7-9700K. R peaks within 2 samples, RMSSD/SDNN/SampEn equal to < 1e-14. Reproduce with tools/neurokit_benchmark.py.

What it does

flowchart LR
    A[raw ECG] --> B[clean<br/>zero-phase or causal]
    B --> C[R peaks<br/>two detectors + bSQI]
    C --> D[artifacts<br/>Kubios or exclusion]
    D --> E[HRV metrics]
    E --> F[window report<br/>valid / warning / suppressed]
    G[signal quality] -.-> F
    H[breathing rate<br/>from ECG] -.-> F
    I[accelerometer<br/>activity, posture] -.-> F
Stage In short Details
Cleaning NeuroKit2-identical zero-phase filter, or a causal streaming filter (optional notch) whose packet-by-packet output equals the whole-record output bit for bit detection.md
R peaks NeuroKit2 and Elgendi detectors, sub-sample refinement, choice of fiducial point, windowed processing of long records, a streaming detector with the batch output detection.md
Signal quality flat line, saturation, kSQI, pSQI, basSQI, bSQI, template correlation, RR plausibility sqi module
Artifacts Kubios correction (NeuroKit2-identical) with a per-beat record of what changed, or an exclusion mode that drops intervals around ectopic beats instead of moving them; gap-aware segments artifacts.md
Metrics time domain, frequency domain (Welch, Burg AR, Lomb–Scargle, NeuroKit2-compatible), Poincaré, entropy, DFA, asymmetry, fragmentation; smoothness-priors detrending metrics.md
Context breathing rate from ECG and an HF band centred on it, accelerometer activity and posture metrics.md
Personal baseline rolling mean / median / CV over calendar days, robust z, smallest worthwhile change, EWMA, CUSUM (statistics only; thresholds stay in the application) metrics.md
Window rules minimum and recommended length for every metric, a per-window verdict with reasons, and coverage-weighted aggregation of short windows metrics.md

How this compares with NeuroKit2, Kubios, pyHRV, hrv-analysis, systole, RHRV and HeartPy, feature by feature: feature matrix.

Plain scalar f64 code with no heavy dependencies: filters, FFT and splines are part of the crate, and nothing assumes a particular CPU (no AVX, no target-cpu=native).

Quick start

From R-peak sample indices:

let rri = fast_hrv::rri_from_peaks(&peaks, 512);   // R-peak indices → NN intervals (ms)
let r = fast_hrv::hrv(&rri);
println!("SDNN {:.1} ms  RMSSD {:.1} ms  LF/HF {:.2}  SampEn {:.2}",
         r.time.sdnn, r.time.rmssd, r.frequency.lf_hf, r.nonlinear.sampen);

From raw ECG, with sub-sample peaks and artifact correction:

use fast_hrv::detect::{ElgendiConfig, RefineConfig, elgendi_peaks, refine_peaks};
let clean = fast_hrv::ecg_clean_zero_phase(&raw, 512.0, &fast_hrv::EcgFilterConfig::default())?;
let cand = elgendi_peaks(&clean, 512.0, &ElgendiConfig::default())?;
let peaks = refine_peaks(&clean, 512.0, &cand, &RefineConfig::default())?;
let fixed = peaks.fix_kubios(512.0, &fast_hrv::KubiosParams::default())?;
let r = fast_hrv::hrv(&fixed.rri_ms(512.0));

Live, 32 samples at a time (the peaks equal the batch result bit for bit):

use fast_hrv::stream::{StreamConfig, StreamDetector, StreamPeaks};
let mut filt = fast_hrv::EcgStreamFilter::new(512.0, &fast_hrv::EcgFilterConfig::default())?;
let mut det = StreamDetector::new(512.0, 0, StreamConfig::default())?;
let mut out = StreamPeaks::default();
for packet in packets {
    det.push(&filt.process(packet), &mut out)?;   // out.primary: confirmed peaks
}
det.flush(&mut out)?;

A runnable version with gaps is in examples/streaming.rs.

Which numbers can be shown

A metric computed on a window is not automatically meaningful: the window may be too short for it, too many beats may have been corrected, or slow breathing may have moved the respiratory peak into the LF band. window_report_rri gives each metric a verdict and the reasons (examples/window_report.rs, 60 s, two corrected beats in a row, breathing 7 /min):

window 60 s, artifact ratio 2.8 %
mean_hr     70.79  valid
rmssd       19.41  warning    consecutive_corrections
sdnn        31.97  warning    below_recommended_length
hf           2.90  warning    below_strict_length, breathing_in_lf_band
lf_hf         NaN  suppressed not_computed, too_short, breathing_in_lf_band
sampen       0.18  suppressed too_short

The length limits come from the metric catalogue (METRICS, metric_info("lf_hf")), with their sources. hrv_with_preset(rri, Preset::KubiosLike) runs a named set of processing choices and returns a Provenance record (library version, preset, detrending, frequency method, intervals used) to store next to the values.

Accuracy

  • Against NeuroKit2 (same input): cleaning, R peaks, Kubios correction, time-domain and nonlinear metrics are identical to ≤ 3.3e-14 relative; frequency_domain_neurokit reproduces nk.hrv_frequency LF/HF to ≤ 3e-13. The default frequency method follows Task Force / Kubios practice and differs from NeuroKit2 by a few percent. Full table: accuracy.md.
  • On annotated real ECG (MIT-BIH Arrhythmia, 18 records, live path): median RMSSD error 0.34 % against the annotated beats (mean 1.6 %, worst 11.8 %) with the default low-amplitude rescue, which fixes detections on P waves; Fiducial::ADAPTIVE brings the mean to 1.2 % and fixes the large errors on bundle branch blocks (detection.md).
  • Not claimed: agreement with a reference device (chest strap, Holter) in the field. Matching NeuroKit2 shows the methods are implemented as specified, not that a wearable recording is measured correctly.

cargo test --release runs the full suite (over 200 tests), including the NeuroKit2 and SciPy parity checks and stream = batch equivalence for any packet size.

Python

pip install fast-hrv (wheels for Linux, macOS and Windows, CPython 3.10–3.14), then import fast_hrv_rs. From a checkout: maturin develop --release.

import fast_hrv_rs as f

f.process_ecg(ecg, 512)                        # clean, R peaks, Kubios correction, basic stats
m = f.hrv(rr_ms)                               # every catalogue metric: {name: value}
m, prov = f.hrv_with_preset(rr_ms, "kubios_like")   # or "task_force", "neurokit"
w = f.window_report(rr_ms, corrected, 15.0)    # w["metrics"]["rmssd"] -> {"value", "verdict", "reasons"}
f.metric_catalogue()["lf_hf"]                  # min / recommended / strict lengths, artifact limit
f.smoothness_priors(rr_ms, 500.0)              # detrended series

live = f.LiveEcg(512, window_s=60, step_s=10)   # live: filter, R peaks, HRV windows
for packet in packets:                          # any size, e.g. 32 samples
    out = live.push(packet)                     # out["peaks"], out["windows"] (verdicts per metric)

Also exclusion and concordance (artifact handling on R-peak positions), the baseline statistics (rolling, robust_z, swc, ewma, cusum), motion_context (accelerometer), ecg_clean, find_peaks, fix_peaks, compute_quality, hrv_metrics and single-metric functions. Wheels are tested on CPython 3.10–3.14.

Features and toolchain

Feature Effect
serde Serialize/Deserialize for report structs
python PyO3 module fast_hrv_rs
simd portable unrolled helpers; no CPU-specific instructions; off by default
parallel reserved, currently no effect

Rust 1.100.0 (rust-toolchain.toml), MSRV 1.85, edition 2024. Changes: CHANGELOG.md; releases: docs/releasing.md. Capacity estimate for a live multi-user pipeline: CAPACITY.md (Turkish).

License

Licensed under either of MIT or Apache-2.0 at your option.

OX Radar and Response Center

Find threats in your stack.

OX Radar can check high-priority threats, like critical package CVEs, against your context.

Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.

Where it’s listed

The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).

  • pypi-releases fast-hrv

References

The publisher’s own links, as the registry reports them. These are not sources for the assessment on this page.

Powered by Read the latest findings

Scan your whole stack

Group 1261154050 1
Group 1261154050
 

From OX Research Newsroom

Vulnerability Insights

OpenSSH Password Authentication Bypass on Alpine Linux (*sshole) – CVE-2026-123158

Vulnerability Insights

Compromised Claude Code extensions (versions 2.1.312 & 2.1.313) in Cursor try to install a backdoor

CVE

Java4Shell (CVE-2026-114938): Easy to Crash, Hard to Exploit — Less Than 0.12% of JVMs Estimated at Risk of RCE

Frame 2085668439 (1)
Group 1261154229