Introducing The Sweep: OX’s New Live Security Research Series
Register Now
Breaking: The 2026 Vulnpocalypse Hits PHP: Four Critical RCEs, but How Dangerous Are They?
Read the Report
Are you exposed? Connect your apps in minutes.
Scan your apps free

msa-gauge-rr

Latest version: vgit:2e78b0164edc914413802f1715b8f0854bce15a7

Overview

Last scanned
19 Nov 2026
Agent skill Publisher: tigerlovefbro
0 Stars
0 Forks
1 Versions
Python Repo language

Scan summary

msa-gauge-rr was last scanned on 19 Nov 2026 at commit 2e78b016. Risk score 1 of 100 (low). No malicious behavior was detected.

  • Releases: Single version.
  • Findings: 1 rule fired in commit 2e78b016 (1 low). The score describes this commit only.

Versions

1 version published
Versions and the rules that fired in each
VersionPublishedStatus
2e78b016 1 rule fired

Rules fired in 2e78b016: 1

Findings

1 Low

Findings for commit 2e78b016. The score is a capped sum of the weights of the rules that fired — not CVSS, not exploitability, and not a probability. It is not comparable across packages with different scan coverage.

Skill mentions tunnel, paste or webhook services

The skill's text or scripts mention a tunneling service such as ngrok or trycloudflare, a Discord webhook, a raw paste link or a public IP address. Legitimate tools reference these too, so this is context for review rather than evidence of harm.

LOW
Checking access…

🔒 Create a free account to see all 1 finding with descriptions and instance counts

The score describes 2e78b016; other versions have their own rules, not their own score.

README

The publisher’s own README, as collected from the registry.

Measurement System Analysis (MSA) / Gauge R&R

When to use

Use this skill when:

  • Qualifying a measurement system for a new part or process (PPAP requirement)
  • Interpreting Gauge R&R results — is this gauge acceptable?
  • Auditing a supplier's MSA study for correctness and adequacy
  • Selecting the right study type for a given measurement situation
  • Investigating a quality problem where measurement error may be a factor
  • Responding to a customer request for MSA data on a specific characteristic

Prerequisites

  • The characteristic to be measured (product or process)
  • The gauge or measurement system to be studied
  • Production parts spanning the expected process variation (10 parts minimum)
  • At least 2 trained appraisers who normally perform the measurement
  • The specification (tolerance) for the characteristic

Workflow

Step 1 — Select the MSA study type
Study type When to use
Gauge R&R (crossed) Variable data, 2–3 appraisers, each measures all parts (most common)
Gauge R&R (nested) Variable data, parts are destroyed during measurement (e.g., tensile test)
Attribute MSA Pass/fail, go/no-go, visual inspection — data is not a number
Bias study Accuracy of a single gauge vs. a reference standard
Linearity study Whether gauge accuracy is consistent across its measurement range
Stability study Whether gauge accuracy drifts over time

For PPAP: Crossed Gauge R&R is required for all variable gauges on special characteristics.


Step 2 — Crossed Gauge R&R study procedure

Setup:

  • Minimum 10 parts selected to represent the full process variation range (not cherry-picked from centre of tolerance)
  • Minimum 2 appraisers (3 preferred)
  • Minimum 2 trials per appraiser per part (3 preferred)
  • Parts randomly numbered and labelled — appraisers must not see each other's measurements
  • Measurement conditions must match normal production conditions

Standard study design:

  • 10 parts × 3 appraisers × 2 trials = 60 measurements
  • 10 parts × 2 appraisers × 3 trials = 60 measurements

Execution:

  1. Appraiser A measures all 10 parts in random order — record results
  2. Appraiser B measures all 10 parts in random order — record results
  3. Appraiser C measures all 10 parts in random order — record results
  4. Repeat the cycle for trial 2 (and trial 3 if applicable)
  5. Appraisers must not see their own previous results or other appraisers' results during the study

Do NOT:

  • Allow appraisers to adjust the gauge between trials
  • Use parts that are all near the nominal value (no spread)
  • Record only one trial (single measurement per appraiser per part is insufficient)

Step 3 — Interpret the results
%GRR (Gauge R&R as % of Total Variation or % of Tolerance)
%GRR Interpretation Decision
< 10% Excellent ✅ Gauge accepted
10% – 30% Marginal ⚠️ May be acceptable based on application — requires engineering review and customer approval
> 30% Unacceptable ❌ Gauge not suitable — investigate and improve before use in production

Two calculation methods:

  • % of Study Variation (% of TV): GRR / Total Variation × 100 — preferred when process is in control
  • % of Tolerance: GRR / Tolerance × 100 — use when process capability is unknown or for attribute gauging

For PPAP, %GRR < 30% (tolerance method) is the typical customer acceptance criterion. \<10% is the target.

Number of Distinct Categories (ndc)

ndc = 1.41 × (Part Variation / GRR)

ndc Interpretation
≥ 5 ✅ Gauge can distinguish adequate number of categories
3 – 4 ⚠️ Gauge can be used for go/no-go decisions only
1 – 2 ❌ Gauge cannot distinguish parts — unacceptable

ndc ≥ 5 is required for measurement systems used on special characteristics.

Repeatability vs. Reproducibility
Component Description Common cause
EV (Equipment Variation / Repeatability) Variation when same appraiser measures same part multiple times Gauge imprecision, worn parts, environment
AV (Appraiser Variation / Reproducibility) Variation between different appraisers measuring the same part Training inconsistency, measurement technique, gauge setup

If EV > AV: investigate gauge (calibration, maintenance, resolution) If AV > EV: investigate training, measurement procedure, gauge fixture/setup

When %GRR > 30% — improving the measurement system

A result >30% means the gauge is not suitable for production use. Do not proceed to PPAP — investigate and retest. Common root causes and actions:

Root cause (high EV) Action
Gauge resolution too coarse Replace with a gauge of finer resolution (rule: resolution ≤ 10% of tolerance)
Gauge worn or damaged Inspect, recalibrate, or replace the gauge
Environmental interference (vibration, temperature) Move measurement to a stable environment; add fixture if needed
Inconsistent part fixturing Design a repeatable fixture or measurement aid
Root cause (high AV) Action
Measurement technique varies by appraiser Develop a standardised measurement instruction (WI with photos/video)
Gauge difficult to read or position Redesign fixture; add a datum locator; use a self-positioning gauge
Training gap Retrain all appraisers using the standardised measurement WI; repeat the study

After implementing improvements: re-run the full study. Do not accept a %GRR > 30% result with a customer waiver unless the characteristic is non-critical and the customer explicitly agrees in writing.


Step 4 — Attribute MSA (pass/fail gauges)

For go/no-go gauges, visual inspection, and any pass/fail decision:

Expanded attribute study (recommended for PPAP):

  • 50 parts spanning the full range (include parts near the accept/reject boundary)
  • 3 appraisers × 3 trials per part = 450 measurements
  • Calculate % agreement (within appraiser and between appraisers)
  • Calculate kappa statistic (Cohen's kappa ≥ 0.9 is acceptable)

Short method (minimum acceptable):

  • 20 parts × 2 appraisers × 2 trials
  • 90% agreement within and between appraisers required
  • Include borderline parts near the specification limit

Step 5 — Audit an existing MSA study

When reviewing a supplier's or internal MSA, check:

  • [ ] Parts selected represent the full process variation range (not all near nominal)
  • [ ] Minimum 10 parts, 2 appraisers, 2 trials confirmed
  • [ ] Appraisers did not see each other's or their own previous results
  • [ ] %GRR result stated clearly (tolerance method or study variation method — which one?)
  • [ ] ndc ≥ 5 for all special characteristics
  • [ ] EV vs. AV breakdown analysed and interpreted
  • [ ] %GRR < 30% (conditional: \<10% preferred)
  • [ ] For attribute gauges: kappa statistic calculated
  • [ ] Study performed in production conditions (not in metrology lab if production measurement is on the line)
  • [ ] Gauge calibration certificate current at time of study

Validation criteria

An MSA study is acceptable for PPAP when:

  • %GRR < 30% (tolerance method) — \<10% preferred
  • ndc ≥ 5
  • Study conducted with production appraisers using production gauges in production conditions
  • Parts selected from the full process variation range
  • Results documented with part numbers, appraiser IDs, gauge ID, and calibration reference

Common mistakes

  • Parts selected near the nominal value only — artificially inflates ndc and understates GRR
  • Appraiser A re-measures all parts immediately — not the same as separate trials (must separate in time)
  • Using metrology lab gauges for an MSA of a production line gauge — study must use the same gauge in the same conditions
  • %GRR > 30% submitted in PPAP without explanation or customer waiver
  • Gauge calibration expired at time of MSA study — study is invalid
  • ndc < 5 on a special characteristic — automatic PPAP finding in IATF audits
  • Attribute MSA with only 2 appraisers and no borderline parts — study has no discriminating power

Output Format

At the start of each use, ask the user:

"How would you like to receive the output? A — Structured Markdown (formatted tables and sections, ready to copy) B — Plain tables (simplified structure for Excel or Word) C — Narrative report (flowing text for a formal document or email)

Default: A."

Adapt all output sections to the chosen format. If the platform or session context already defines a format preference, skip this question.

Changelog

Version Date Author Change
1.0 2026-06-06 @RBraga01 Initial release
1.1 2026-06-06 @migmcc Added improvement guidance for %GRR > 30% — root cause table for high EV and high AV with corrective actions

OX Radar and Response Center

Find threats in your stack.

OX Radar can check high-priority threats, like critical package CVEs, against your context.

Each incident is marked Detected or Not Detected with a remediation plan and proof all tracked in the Response Center.

Where it’s listed

The probe returned only these fields for this server — auth requirement, protocol and tool list weren’t observed, so they’re not shown (never guessed).

  • GitHub tigerlovefbro/codex-plugins/msa-gauge-rr

References

The publisher’s own links, as the registry reports them. These are not sources for the assessment on this page.

Scan your whole stack

Group 1261154050 1
Group 1261154050
 

From OX Research Newsroom

CVE

Java4Shell (CVE-2026-114938): Easy to Crash, Hard to Exploit — Less Than 0.12% of JVMs Estimated at Risk of RCE

Critical Apache HTTP Server Flaw Exposes Web Servers to RCE (1)
CVE

CVE-2026-119618: Critical Apache HTTP Server Flaw Exposes Web Servers to Remote Code Execution

Copy of Template Design OX Blog (3)
Research

Ruby2Shell: Ruby Memory Corruption Flaws Expose Applications to Remote Code Execution, But is it an Actual Risk?

Frame 2085668439 (1)
Group 1261154229